Model No: NTS4000

In/out head, 40 Lpm 25mm connection

Acidic water can cause corrosion of pipe-work and seals in the water line, causing costly damage. When water drops below 7 pH it becomes acidic (depending how low the pH drops) and may begin dissolving copper from your pipes. This reaction results to the green and blue stain on your tap fittings, in your sink, bath and shower recesses. These units effectively utilise a calcium carbonate media to lift the pH, which slowly dissolves into the water protecting the plumbing system from corrosion.

Got blue-green stain on your sinks and tap?
When water drops below 7 pH it becomes acidic (depen ding how low the pH drops) and may begin dissolving copper from your pipes. This reaction results to the green and blue stain on your tap fittings, in your sink, bath and shower recesses. The Puretec NTS4000 is designed to correct the pH of your water. These units effectively utilise a calcium carbon ate media to lift the pH, which slowly dissolves into the water.
$1,456.71 Incl. GST*
*Price listed is suggested retail price. Reseller price may vary.

Features & Benefits

• Neutralise potentially corrosive water with a low pH.
• Utilises calcium carbonate media to lift the pH.
• Slow reacting for controlled pH correctors.
• Media fill port for easy maintenance.
• 1inch connections means minimum pressure loss.
• Upflow configuration for reliable performance.
• No power required.

Specifications

Ordering Code
NTS4000
Valve
In/out head
pH Range
5.0 - 7.0
Flow Rate
40 Lpm
Maximum Flow Rate
90 Lpm
Connection
1” Male Inlet/Outlet
Min/Max Pressure
200 - 600 kPa
Operating Temperature
5-40°C (41-104°F)
Warranty
1 year^
Replacement Media Kits
WTM2000-15L (Replacement neutralising media, 15 litres)
Accessories
WTV5000 - Bypass assembly for testing, and maintenance.
WTV5050 - Blending valve for partial hardness removal.
WTD888 - Funnel for easy refilling of media.
WTM2500 - Neutramax neutralising high capacity media.
Operating Conditions: 1. Neutralising media is consumed according to pH level and needs to be replaced periodically. **pH range outside these parameters may be accommodated - speak to our Water Treatment Specialists.